upon N: NONE Reaction upon A: NONE Acknowl. if message output above speed threshold, reduce filter time if necessary (p0438). adapt the parameter for the clearance between zero marks (p0425). check whether the coding disk is dirty or there are strong ambient magnetic fields. Siemens SINAMICS S210 Remedy: - check that the encoder cables are routed inĬompliance with EMC. activate/check the parameters of the motor temperature model (p0612, p0626 and check the monitoring limits (p0604, p0605). check the motor ambient temperature and cooling. Alarm value (r2124, interpret decimal): this is the number of the temperature channel leading to the message. PTC: The response threshold of 1650 Ohm was exceeded. Siemens SINAMICS S210 Cause: KTY84/PT1000: The motor temperature has exceeded theĪlarm threshold (p0604, p0616). Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: dd = connection number (%4) cc = component number (%3) bb = component class (% 2) aa = component number of the component that has not been inserted (% 1) Note: The component is described in dd, cc and bb, where the component has not been inserted. Reaction: NONE Acknowledge: NONE Cause: The topologyĬomparison has detected a DRIVE-CLiQ component missing in the actual topology with respect to the target topology. Note regarding the message value: The individual information is coded as follows in the message value (r0949/r2124): 0000yyxx hex: yy = component number, xx = error 64 (= 40 hex): Timeout in the telegram send list. 34 (= 22 hex): Timeout in the telegram receive list. Fault cause: 33 (= 21 hex): The cyclic telegram has not been received. The nodes do not send and receive in synchronism. The Control Unit to the encoder concerned. Siemens SINAMICS S210 Cause: A DRIVE-CLiQ communication error has occurred from Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: dd = connection number (%4) cc = component number (%3) bb = component class (% 2) aa = component number of the incorrectly inserted component (% 1) Note: The component is described in dd, cc and bb, where the component involved is incorrectly inserted.
#SIMATIC MANAGER COPY RAM TO ROM INSTALL#
Save the firmware version that you would like to install on the converter on a blank SD card (Ĭause: The topology comparison has detected a controllerĮxtension 32 (CX32) in the actual topology that has been incorrectly inserted with respect to the target topology. Proceed as follows to perform an upgrade or downgrade: 1. During a downgrade to an older firmware version, the converter is reset to the factory settings. Settings made before the upgrade will be retained. You can also install an older firmware version to always provide the same machine configurations.
#SIMATIC MANAGER COPY RAM TO ROM UPDATE#
Siemens SINAMICS S210 6.14 Firmware update You have the option of upgrading yourĬonverter to a newer firmware version.